Cryogenic liquid storage tanks and supporting gasification equipment were supplied under TAIDA GLOBAL’s coordination for an industrial gas storage and distribution project in India.
The customer required a centralized storage solution for low-temperature industrial liquids while keeping the installation layout compact and allowing sufficient access for operation, inspection, and maintenance. Based on the project conditions, vertical cryogenic storage tanks were selected for the main storage area, together with related piping, valves, safety devices, and vaporization equipment.
Before shipment, the tank bodies, piping connections, lifting points, insulation systems, surface finish, valves, and transport supports were inspected according to the confirmed project requirements.
Due to the dimensions and center of gravity of the equipment, the loading and transportation plan included dedicated support structures, protection for exposed valves and pipelines, and reinforced securing arrangements. The equipment was then prepared for export transportation to India.
The supplied system included:
Vertical cryogenic liquid storage tanks
Outdoor cryogenic storage equipment
Ambient vaporization units
Piping and valve assemblies
Safety and pressure-control components
Equipment support structures
Transport and installation accessories
The final equipment configuration was adjusted according to the stored medium, required capacity, working pressure, site layout, operating conditions, and applicable project specifications.
Vertical cryogenic liquid storage tank:
Tank capacity range: 5–250 m³
Configuration: Vertical
Applicable media: LNG, LO₂, LN₂, LAr, and LCO₂
Working pressure: 0.8–2.1 MPa
Minimum design metal temperature: subject to the selected medium and project specification
Insulation type: Vacuum powder insulation or high-vacuum multilayer insulation
Main materials: Subject to the selected configuration and applicable technical requirements
Non-destructive testing requirements: Confirmed according to the project specification
Piping and valve arrangement: Customized according to the operating process
Installation arrangement: Adjusted according to the site layout and maintenance requirements
The final tank capacity, working pressure, insulation system, material selection, piping arrangement, valve configuration, and foundation interface must be confirmed through the customer’s technical specification and site drawings.
The vertical configuration was selected to reduce the required installation footprint while providing centralized storage capacity for the industrial gas system.
For projects with limited installation space, vertical tanks can help organize multiple storage units within a controlled area. However, the final layout must also consider:
Foundation design
Tank spacing
Fire and safety distances
Piping routes
Vehicle and maintenance access
Vaporizer location
Valve operating space
Future expansion requirements
The equipment layout should therefore be reviewed as a complete system rather than as individual tanks.
Before delivery, the project team reviewed the equipment against the approved technical documents and scope of supply.
The inspection points included:
Tank body condition
Nozzle and piping orientation
Valve installation
Safety-device interfaces
Vacuum-insulation system
Lifting points
Support structures
Surface coating and finish
Equipment identification
Export transport protection
Any project-specific test records, material documents, inspection reports, or third-party inspection requirements should be confirmed before production and included in the agreed documentation list.
Cryogenic tanks require a transportation plan based on equipment dimensions, weight, center of gravity, valve position, and route conditions.
For this project, exposed components were protected before loading, while the tank bodies were supported and secured to reduce movement during transport. The loading arrangement also considered lifting access and unloading preparation at the destination site.
For international projects, buyers should confirm:
Delivery destination
Port and inland transport conditions
Maximum transport dimensions
Unloading equipment
Site access restrictions
Required export packaging
Protection of valves and pipelines
Installation sequence after arrival
These details can affect the final equipment arrangement and shipment plan.
TAIDA GLOBAL supported the Indian customer with technical requirement clarification, equipment configuration coordination, production follow-up, quality inspection, export packaging, loading preparation, and delivery planning.
The project scope was coordinated around the customer’s operating medium, storage requirements, site conditions, installation layout, and required documentation.
For similar cryogenic storage projects, buyers should provide the following information before equipment selection:
Stored medium
Required storage capacity
Working and design pressure
Daily gas consumption
Required vaporization capacity
Minimum and maximum site temperature
Installation location
Site layout drawing
Available power supply
Applicable standards
Required inspection documents
Delivery destination
Installation and commissioning scope
Final technical parameters should be confirmed based on the project specification and applicable requirements.
TAIDA GLOBAL helps global B2B buyers coordinate cryogenic equipment sourcing, technical clarification, supplier matching, quality inspection, export packaging, logistics, installation preparation, spare parts, and after-sales support.
Same Quality Standard. Lower Total Procurement Cost.
